Description🔗
The inletOutletTotalTemperature
is a temperature boundary condition that provides
an outflow condition for total temperature for use with supersonic cases, where
a user-specified value is applied in the case of reverse flow.
Usage🔗
The condition requires entries in both the boundary
and field files.
Boundary file🔗
<patchName>
{
type patch;
...
}
Field file🔗
<patchName>
{
// Mandatory entries
type inletOutletTotalTemperature;
T0 <scalarField>;
gamma <scalar>;
// Optional entries
U <word>;
psi <word>;
phi <word>;
// Inherited entries;
...
}
where:
Property | Description | Type | Required | Default |
---|---|---|---|---|
type |
Type name: inletOutletTotalTemperature
|
word | yes | - |
T0 |
Total temperature patch field | scalarField | yes | - |
gamma |
Heat-capacity ratio | scalar | yes | - |
U |
Name of velocity field | word | no | U |
psi |
Name of compressibility field | word | no | psi |
phi |
Name of flux field | word | no | phi |
The inherited entries are elaborated in:
- inletOutletFvPatchFields.H
Method🔗
N/A
Further information🔗
Tutorial:
- N/A
Source code:
API:
History: